Wednesday, May 6, 2020

Essay on Redox Titration Lab Report - 750 Words

Determination of Fe by Redox Titration Matt Cuff Quant 320L October 21, 2011 Abstract In this experiment the percent of iron in an unknown sample will be determined by using a redox titration and then compared to a different method. A primary standard which in this case is ferrous ammonium sulfate will be used to standardize potassium dichromate. The standardized potassium dichromate will then be used to titrate the unknown iron sample using the indicator p-diphenylamine sulfonate. The standardized potassium dichromate which has a concentration around 0.017 M is then titrated into the unknown iron sample which is dissolved in deionized water. The unknown sample is titrated to its end point using the indicator p-diphenylamine†¦show more content†¦Then use this information to calculate the percent iron in the unknown sample. The only obvious observations that could be made in the experiment was the color change of the solution from green to purple due to the indicator p-diphenylamine sulfonate and also titrating the solution with potassium dichromate. Data Analysis Trial 1 Trial 2 Trial 3 Trial 4 Wt. Fe(NH)2(SO4)2 , g 0.5025 g 0.5010 g 0.5003 g 0.5013 g Vol. K2Cr2O7 , mL 13.72 mL 14.22 mL 13.83 mL 13.69 mL Wt. Unknown , g 0.5020 g 0.5020 g 0.5022 g 0.5004 g Vol. K2Cr2O7 , mL 9.07 mL 10.18 mL 9.53 mL 9.78 mL % Iron in sample 10.29% 11.55% 10.85% 11.11% Trial 1 10.29% Fe Trial 2 11.55% Fe Trial 3 10.85% Fe Trial 4 11.11% Fe Mean 10.95% Fe STD  ± 0.5% Fe RSD  ± 0.05% Fe Calculations [K2Cr2O7] = 0.017 M 9.07 mL K2Cr2O7 * 0.017 M = [pic] Spooled =[pic] Spooled = 9.20 tcalc = [pic] tcalc = 1.197 @ 90% ttable = 1.90 ttable tcalc The two methods are statistically comparable Fcalc = [pic] Fcalc = 676 Ftable = 9.28 Fcalc Ftable The variances of the two methods are statistically different The average percent of iron present in the unknown sample was 10.95% Fe with a standard deviation of  ± 0.5% Fe. When statistically compared to an alternative method of determining percent iron in the same unknown sample using Beer’sShow MoreRelatedChemistry Lab Report for Vitamin C Estimation by Back(Idiometric) Titration3329 Words   |  14 Pagesback(idiometric) titration Mahindra (UWC of India) Chemistry lab report for back titration Name: Ashenafi Asfaw Beyene Back (Indirect) Titration Vitamin C estimation by Back Titration Table1: The amount of volume (in cm3) and concentration (in M) of KI, KIO3, and H2SO4 which were used in the experiment of Vit C estimation by back titration. VKI addedRead MoreCOMPLEXOMETRIC DETERMINATION OF WATER HARDNESS LAB2098 Words   |  9 Pagesthe mixture prior to the titration to capture the calcium metal ions so the indicator can work properly. The experiment adds 4 drops of Eriochrome Black T as the indicator to visually see the color change as complexes are formed and the solution undergoes chelation of metal impurities. The color change from indicator starts as pink and changes to a violet then light blue color to signify the chemical phase changes throughout the reaction until the endpoint. 3 titrations are experimentally conductedRead MoreTitration Research Paper3106 Words   |  13 PagesQuantitative Chemistry –Titration Determination of the Molarity of an Unknown Solution through Acid-Base Titration Technique 1. Introduction 1.1 Aim The aim of this investigation was to determine the precise molarity of two (NaOH(aq)) sodium hydroxide solutions produced at the beginning of the experiment through the acid-base titration technique. 1.2 Theoretical Background Titration is a method commonly used in laboratory investigations to carry out chemical analysisRead MoreSynthesis and Component Analysis of an Iron (Iii) Oxalate Complex7868 Words   |  32 PagesExperiments 4A-C: Synthesis and Component Analysis of an Iron (III) Oxalate Complex My Name TA, Section B## Work Performed on 10/23, 10/30, 11/4, 200# Report due Tuesday, November ##, 200# 1. Abstract This experiment initially involved the synthesis of an iron (III) oxalate complex with the general formula Kw[Fex(C2O4)y] ·zH2O. The variables x, y, and z were determined through the duration of the entire experiment. From 1.2000g of Fe(NH4)2(SO4)2 were synthesized 1.1###g of K3[FeIII(C2O4)3] ·3H2ORead MoreSynthesis and Component Analysis of an Iron (Iii) Oxalate Complex7868 Words   |  32 PagesExperiments 4A-C: Synthesis and Component Analysis of an Iron (III) Oxalate Complex My Name TA, Section B## Work Performed on 10/23, 10/30, 11/4, 200# Report due Tuesday, November ##, 200# 1. Abstract This experiment initially involved the synthesis of an iron (III) oxalate complex with the general formula Kw[Fex(C2O4)y] ·zH2O. The variables x, y, and z were determined through the duration of the entire experiment. From 1.2000g of Fe(NH4)2(SO4)2 were synthesized 1.1###g of K3[FeIII(C2O4)3] ·3H2ORead MoreChem 1212k Lab Report Essay1341 Words   |  6 PagesDeborah Bell April 17, 2012 Chemistry 1212K Lab Synthesis Report Introduction In this Chemistry Lab the main objective is to perform accurate chemical analysis for the quantity of elements and compounds in a sample. There will be a compound made then synthesized. The methods used were acid-base titrations, redox titrations, gravity filtration, and distillation. General conclusions included Procedures Weight of Crucibles 1. The first experiment is Preparation of a Cobalt AmineRead MoreMicroelectronic Pill8918 Words   |  36 Pagesdeliver enhanced functionality, reduced size and power consumption, through system-level integration on a common integrated circuit platform comprising sensors, analog and digital signal processing, and signal transmission. In this report, we present a novel analytical micro system which incorporates a four-channel micro sensor array for real-time determination of temperature, pH, conductivity and oxygen. The sensors were fabricated using electron beam and photolithographic patternRead MoreBiology Vitamin C Lab Report4458 Words   |  18 PagesBIOLOGY LAB REPORT TITLE: DETERMINING THE VITAMIN C CONTENT IN VARIOUS FRUIT JUICE PREPARED BY: NOR HUSNA BINTI MOHD ROSLI CLASS: SC3 (ALUK 11) IC NUMBER: STUDENT ID: LECTURER’S NAME: MADAM ZAKIAH BINTI ZAKARIA SUBMISSION DATE: 22 AUGUST 2013 OBJECTIVES: To investigate the vitamin C content in various fruit juices which is based on the graph’s curve obtained. INTRODUCTION [pic] Vitamin C, or also known as ascorbic acid (L-ascorbic and L-dehydroascorbicRead MoreEssay about Basic Chemistry for Investigating Living Systems7868 Words   |  32 PagesStem(Dependent Variable) | 1 Biuret Reagent - 4 mL in Pipet(Dependent Variable) | | | | Quantity/Materials (Independent and Dependent Variables) Methodologies/Observations/Hypotheses/Results/Conclusions: Preparations Required Prior to Performing Lab Exercises: 1% Albumen Solution Preparation, used in Exercises 1, 2, 3, 4: Place only the translucent (referred to as the â€Å"egg white†) part of an egg into a clean bowl. Avoid adding any white opaque-colored membrane material. Mix the egg white well

No comments:

Post a Comment

Note: Only a member of this blog may post a comment.